11 switching from phase – Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual
Page 309

7.2 Motions After Switching Motion Commands
7.2.11 Switching from PHASE
7-39
Switching Commands during Execution
7.2.11 Switching from PHASE
Switched From
Switched To
Operation
PHASE
NOP
PHASE will immediately switch to NOP, and the moving amount stored in the accelera-
tion/deceleration filter will be output.
POSING
PHASE will immediately switch to POSING, and the control mode will change from
phase control mode to position control mode.
The value of the Position Reference Setting (OL
1C) when the motion command is
switched will be as follows.
09, bit 5 = 0)> Incremental value = Target position − IL 14 (DPOS) OL 1C = OL 1C+ Incremental value 09, bit 5 = 1)> OL 1C = Target position PHASE NOP PHASE NOP Phase control mode Position control mode PHASE The amount stored in the acceleration/deceleration filter will be output. Motion command response PHASE POSING PHASE POSING Phase control mode Position control mode PHASE POSING The speed will smoothly change. (The speed at the time the motion com- mand is switched will increase/decrease until it reaches the target speed of POSING.) Motion command response
Motion command
Motion command