Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual
Page 398

10.4 Motion Parameter Details
10.4.2 Setting Parameter List
10-34
OW
42
Auxiliary Inverter User Constant Number
Setting range: 0 to FFFFH
Sets the leading number of user constants to read by exe-
cuting the subcommand Read User Constant, or the lead-
ing number of user constants to write by executing the
subcommand Write User Constant.
Set the register numbers to be set or read for
MEMOBUS transmission.
OW
43
Auxiliary Inverter User Constant Number Size
Setting range: 1 to 4
Sets the size of user constants to read for the subcom-
mand Read User Constant, or the size of user constants to
write for the subcommand Write User Constant.
All inverter constants are composed of one word. There-
fore, setting the Inverter User Constant Number Size
enables the reading or writing of data of 1 to 4 consecu-
tive words at once.
OW
44
Auxiliary Inverter User Constant
Set Point 1
Setting range: 0 to 65535
Sets the data to write for the subcommand Write User
Constant.
Valid when Auxiliary Inverter User Constant Number
Size = 1 to 4.
OW
45
Auxiliary Inverter User Constant
Set Point 2
Setting range: 0 to 65535
Sets the data to write for the subcommand Write User
Constant.
Valid when Auxiliary Inverter User Constant Number
Size = 2 to 4.
OW
46
Auxiliary Inverter User Constant
Set Point 3
Setting range: 0 to 65535
Sets the data to write for the subcommand Write User
Constant.
Valid when Auxiliary Inverter User Constant Number
Size = 3 or 4.
OW
47
Auxiliary Inverter User Constant
Set Point 4
Setting range: 0 to 65535
Sets the data to write for the subcommand Write User
Constant.
Valid when Auxiliary Inverter User Constant Number
Size = 4.
OW
48
Fixed Parameter Number
Setting range: 0 to 65535
Sets the fixed parameter number to read for the subcom-
mand Read Fixed Parameters.
OW
49
to
OW
6F
−
Reserved by the system
OW
70
Transmission Reference Output Data 0
Setting range: 0 to FFFFH
This will be sent as the 1st word of the command Trans-
mission Reference.
OW
71
Transmission Reference Output Data 1
Setting range: 0 to FFFFH
This will be sent as the 2nd word of the command Trans-
mission Reference.
OW
72
Transmission Reference Output Data 2
Setting range: 0 to FFFFH
This will be sent as the 3rd word of the command Trans-
mission Reference.
OW
73
Transmission Reference Output Data 3
Setting range: 0 to FFFFH
This will be sent as the 4th word of the command Trans-
mission Reference.
OW
74
Transmission Reference Output Data 4
Setting range: 0 to FFFFH
This will be sent as the 5th word of the command Trans-
mission Reference.
OW
75
Transmission Reference Output Data 5
Setting range: 0 to FFFFH
This will be sent as the 6th word of the command Trans-
mission Reference.
Register No.
Name
Contents