4.4 MP2000 Series Machine Controller Parameter Details

4.4.2 Motion Setting Parameter Details

4-53

Motion Parameters

A typical example of a zero point return operation is shown below.

Refer to 6.2.3 Zero Point Return (ZRET) for details.

( 26 ) Step Travel Distance

OL

40

Creep Rate

Setting Range

Setting Unit

Default Value

−2

31

to 2

31

−1

Depends on

Speed Units.

500

Description

Set the creep speed for a zero point return operation after the ZERO signal is detected.

The setting unit for this parameter depends on the Speed Unit Selection (OW

03, bits 0 to 3), but

the result of applying the speed unit setting is not shown here.

OL

42

Zero Point Return Travel Distance

Setting Range

Setting Unit

Default Value

−2

31

to 2

31

−1

Reference unit

0

Description

Set the distance from where the signal is detected to the zero point position.

Position

Phase

Speed Torque

Position

Phase

Speed Torque

Speed

Start

OL

40㧕

OL

42㧕

DEC signal

Phase-C pulse

Creep Rate

Zero Point Return

Travel Distance

Width of

Starting

Point

Position

Output

OL

3E㧕

Approach Speed

OL

10㧕

Speed Reference

Setting

Position

OL

44

Step Travel Distance

Setting Range

Setting Unit

Default Value

0 to 2

31

−1

Reference unit

1000

Description

Set the moving amount for STEP commands.

Refer to 6.2.7 Relative Position Mode (STEP) (Step Mode) for details on STEP commands.

R

Position

Phase

Speed Torque

(%)

(OL

10)

(OL

44)

100%

Speed

Time

Straight Line

Acceleration

Time Constant

(OL

36)

Straight Line

Deceleration

Time Constant

(OL

38)

Rated speed

Speed

Reference

Setting

Step Travel

Distance