background image

4.4 MP2000 Series Machine Controller Parameter Details

4.4.2 Motion Setting Parameter Details

4-30

[ b ] Details of Latch Operations

Usual Latch Operation

Check the completion of the latch with bit 2 of IW

0C.

To repeat latching again, set bit 4 of OW

00 to 1.

• Condition: Latch at phase-C pulse
• Settings:

Motion setting parameters

Servo parameters

Pn850 Setting

Latch Operation

Latch Single Setting

= 0

– (Error)

> 0

Continuous Latch Operation

Setting with Pn852 and Pn853

Latch Detection Demand

OW

00.bit 4

Continuous Latch Mode

= 1

Continuous Latch Operation

(Latch signals are set in Pn852 and Pn853.)

Setting Error

(Warning in SERVOPACK)

Usual Latch Operation

(Latch signals are set in bits 0 to 3

of OW

04.)

Usual Latch Mode

OW

01.bit 6

= 0

> 0

= 0

Register No.

Name

Setting value

OW

01

Mode Setting 1

Bit 6: Latch mode selection = 0 (usual latch)

OW

04

Function Setting 2

Bits 0 to 3: Latch Detection Signal Selection = 2 (Phase-C pulse)

Parameter No.

Name

Setting value

Pn850

Latch Sequence Number

Disabled

Pn851

Continuous Latch Count

Disabled

Pn852

Latch Sequence Signal 1 to 4 Setting

Disabled

Pn853

Latch Sequence Signal 5 to 8 Setting

Disabled