10.4 Motion Parameter Details

10.4.3 Monitoring Parameter List

10-37

Settings for Connecting Inverters

IL

04

Alarm

Bits 0 to E

Reserved by the system

Bit F: User Constant Error

Not used

Bit 10: Synchronization
Communication Error

Turns ON when SVB Module watchdog timer timeout
error is detected.

Valid when the WDT Abnormality Detection Mask
bit of the fixed parameter Function Selection Flag 2 is
set to Disabled.
This alarm can be cleared by executing Alarm Clear.

Bit 11: Communication
Warning

Turns ON when communication error occurs.

Valid when:
Communication Abnormality Detection Mask bit of
the fixed parameter Function Selection Flag 2 is set to
Disabled, and Alarm is selected for Communication
Selection is Abnormal of the fixed parameter Func-
tion Selection Flag 3.
This alarm can be cleared by executing Alarm Clear.

Bit 12: Communication
Timeout Error

Turns ON when no response to the sent command or
subcommand has been returned from the Inverter for
five seconds.

This alarm can be cleared by executing Alarm Clear.

Bits 13 to 1F

Reserved by the system

IW

06

Reserved by the system

IW

07

Reserved by the system

IW

08

Command
Response Code

00: No Command

No command is selected.

01: Inverter Drive Control

Control Inverter Drive is selected.

02: Read User Constant

Read User Constant is selected.

03: Write User Constant

Write User Constant is selected.

04: Alarm Monitor

Alarm Monitor is selected.

05: Alarm History Monitor

Alarm History Monitor is selected.

06: User Constant RAM
Writing

User Constant RAM Writing is selected.

07: User Constant
EEPROM Writing

User Constant EEPROM Writing is selected.

08: Transmission Reference Transmission Reference is selected

IW

09

Command Status

Bit 0: Command Execution
Flag

ON during command execution

Always ON when Transmission Reference command
is selected.

Bits 1and 2

Reserved by the system

Bit 3: Command Error
Completed Status

Turns ON when the command execution ends with an
error.

Bits 4 to 7

Reserved by the system

Bit 8: Command Execution
Completed

Turns ON when command execution is completed.

With a Inverter Drive Control command, data input
and output will continue after command execution is
completed.
Always ON when No Command is selected.

Bits 9 to F

Reserved by the system

IW

0A

Subcommand
Response Code

00: No Command

No subcommand is selected.

01: Inverter I/O Control

Inverter I/O Control is selected.

02: Read User Constant

Read User Constant is selected.

03: Write User Constant

Write User Constant is selected.

04: Alarm Monitor

Alarm Monitor is selected.

05: Alarm History Monitor

Alarm History Monitor is selected.

08: Transmission Reference Transmission Reference is selected.
09: Read Fixed Parameters

Read Fixed Parameters is selected.

Register No.

Name

Contents