beautypg.com

G.6 motion command details, A-29, 2 ) zero point return (zret) – Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual

Page 518

background image

Appendix G Settings when Connecting MECHATROLINK-II Compatible Stepping Motor Drivers

G.6 Motion Command Details

A-29

Appendices

G.6

Motion Command Details

( 1 ) Latch Torque Positioning (EX_POSING) (External Positioning)

The axis motion depends on the setting of the External Positioning Move Distance Parameter Options (bit 9) of the
stepper parameter Parameter Switch (0000h).

( 2 ) Zero Point Return (ZRET)

The setting parameter Zero Point Return Method (OW

3C) is invalid and will be ignored.

Select the latch signal for zero point return motion by using Latch Detection Signal Selection bits 0 to 3 of the setting
parameter Function Setting 2.
The axis motion depends on the setting of Zero Point Return Speed Parameter Options (bit 10) and Home Offset
Parameter Options (bit 11) of the stepper parameter Parameter Switch (0000h).

( 3 ) Change Acceleration Time (ACC)

( 4 ) Change Deceleration Time (DCC)

Parameter Switch (0000h),

bit 9: External Positioning Move Distance

Parameter Options

Operation

0: Standard Parameter

The external positioning will be carried out using the value set in the setting
parameter External Positioning Final Travel Distance (OL

46) as the move

amount after the external signal input.

1: Unique Parameter

The external positioning will be carried out using the stepper parameter of the
stepper model as the move amount after the external signal input.

Parameter Switch (0000h)

Operation

0: Standard Parameter

The zero point return will be carried out according to the following parameter
settings:
OW

09 Motion Command Control Flag, bit 3: Zero Point Return Direction

Selection
OL

3E: Approach Speed

OL

40: Creep Rate

OL

42: Zero Point Return Travel Distance

1: Unique Parameter

The zero point return will be carried out according to the parameter of the stepper
model.

Parameter Switch (0000h),

bit 8: Acceleration/Deceleration Rate

Parameter Options

Operation

0: Standard Parameter

The values determined by the following setting parameters will be written into
stepper parameters:
OW

03 Function setting 1, bits 4 to 7: Acceleration/Deceleration Degree Unit

Selection
OL

36: Straight Line Acceleration/Acceleration Time Constant

1: Unique Parameter

The values determined by the setting parameters will not be written into the step-
per parameters. The execution will be normally completed.

Parameter Switch (0000h),

bit 8: Acceleration/Deceleration Rate

Parameter Options

Operation

0: Standard Parameter

The value determined by the following setting parameter will be written to the
stepper parameter.
OW

03 Function Setting 1, bits 4 to 7: Acceleration/Deceleration Degree

Unit Selection
OL

38: Straight Line Deceleration/Deceleration Time Constant

1: Unique Parameter

Writing to the stepper parameter will not be implemented. The execution will be
normally completed.