11.6 Parameters That Are Automatically Updated
11.6.1 Parameters Updated when a MECHATROLINK Connection Is Established (1) (User Constants Self-writing Function Enabled)
11-21
Utility Functions
11.6 Parameters That Are Automatically Updated
Some of the parameters stored in SERVOPACK RAM may be overwritten automatically under certain conditions or as
a result of self-configuration. This includes MP2000-series Machine Controller setting parameters and fixed parame-
ters, as well as fixed value SERVOPACK parameters. Some SERVOPACK parameters are also written to setting
parameters automatically during self-configuration. The parameters that are updated automatically under specific con-
ditions are listed in the following tables.
Refer to Chapter 4 Motion Parameters for details on Machine Controller parameters. Refer to your SERVOPACK
manual for details on SERVOPACK parameters.
11.6.1 Parameters Updated when a MECHATROLINK Connection Is Established (1)
(User Constants Self-writing Function Enabled)
The Machine Controller parameter settings in the left table below are automatically written to the SERVOPACK
parameters given in the right table below when a connection is established between the Machine Controller and the
SERVOPACK. This occurs after power is turned ON or alarms are cleared following a communication interruption.
The parameters are written only when User Constants Self-writing Function is enabled when bit A of fixed parameter 1
in the Machine Controller is set to 0.
* 1. Updated when using MECHATROLINK-II (10 Mbps, 32 bytes).
* 2. When Pn833.0 is set to 0, Pn80B will be updated. When Pn833.0 is set to 1, Pn836 will be updated.
* 3. When Pn833.0 is set to 0, Pn80E will be updated. When Pn833.0 is set to 1, Pn83C will be updated.
MP2000-Series Machine Controller
SERVOPACK Parameter
Remarks
SGD-N, SGDB-N NS100
NS115
SGDS
SGDV
Setting p
ara
meters
Width of Positioning
Completion
OL
1E
→
−
−
Pn500
*1
Pn522
*1
* Settings are written only
when using a MECHA-
TROLINK-II operating at 10
Mbps in 32-byte mode.
Position Loop Gain
OW
2E
→
−
−
Pn102
*1
Speed Loop Gain
OW
2F
→
−
−
Pn100
*1
Speed Feed
Forward
Amends
OW
30
→
−
−
Pn109
*1
Position Integration
Time Constant
OW
32
→
−
−
Pn11F
*1
Speed Integration
Time Constant
OW
34
→
−
−
Pn101
*1
Straight Line Accel-
eration/Acceleration
Time Constant
OL
36
→
Cn-0020
Pn80B
Pn80B/
Pn836
*2
Settings are written regardless of the
communication method.
Straight Line Decel-
eration/Decelera-
tion Time Constant
OL
38
→
−
Pn80E
Pn80E/
Pn83C
*3
Filter Time Constant
OW
3A
→
Cn-002E
Pn811
When “Expo-
nential Accelera-
tion/
Deceleration Fil-
ter” is selected
for filter type.
Settings are writ-
ten regardless of
the communica-
tion method.
→
Cn-0026
Pn812
When either
“Without filter”
or “Moving
Average Filter”
is selected for
filter type.
Filter Type Selection
OW
03
Bits 8 to B →
Settings are automatically enabled.