background image

6.2 Motion Command Details

6.2.10 Change Deceleration Time (DCC)

6-57

Motion Commands

[ b ] Monitoring Parameters

( 4 ) Timing Charts

[ a ] Normal End

[ b ] Error End

Parameter

Name

Monitor Contents

IL

02

Warning

Stores the most current warning.

IL

04

Alarm

Stores the most current alarm.

IW

08

Motion Command
Response Code

Indicates the motion command that is being executed.
The response code will be 11 during DCC command execution.

IW

09

Bit 0

Command Execution Flag

Turns ON during DCC command execution and turns OFF when execution has
been completed.

IW

09

Bit 1

Command Hold Completed

Always OFF for DCC command.

IW

09

Bit 3

Command Error Completed
Status

Turns ON if an error occurs during DCC command execution.
Turns OFF when another command is executed.

IW

09

Bit 8

Command Execution
Completed

Turns ON when DCC command execution has been completed.

OW

08 = 11 (DCC)

IW

08 = 11 (DCC)

IW

09, bit 0 (BUSY)

IW

09, bit 8 (COMPLETE)

IW

09, bit 3 (FAIL)

Undefined length

of time

OW

08 = 11 (DCC)

IW

08 = 11 (DCC)

IW

09, bit 0 (BUSY)

IW

09, bit 8 (COMPLETE)

IW

09, bit 3 (FAIL)

Undefined length

of time