beautypg.com

Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual

Page 316

background image

8.1 Position Control

8.1.1 Motion Parameters for Position Control

8-4

OL

4C

Number of POSMAX Turns Presetting Data

Rev

0

-2

31

to 2

31

−1

OW

4E

Servo User Monitor Setting

0E00H

Bit setting

OW

4F

Servo Driver Alarm Monitor No.

0

0 to 10

OW

50

Servo Driver User Constant No.

0

0 to 65535

OW

51

Servo Driver User Constant Size

1

1, 2

OL

52

Servo Driver User Constant Set Point

0

-2

31

to 2

31

−1

OW

54

Servo Driver for Assistance User Constant No.

0

0 to 65535

OW

55

Servo Driver for Assistance User Constant Size

1

1, 2

OL

56

Servo Driver for Assistance User Constant Set
Point

0

-2

31

to 2

31

−1

OW

5C

Fixed Parameter Number

0

0 to 65535

OL

5E

Encoder Position When Power is OFF (Lower 2
words)

pulse

0

-2

31

to 2

31

−1

OL

60

Encoder Position When Power is OFF (Upper 2
words)

pulse

0

-2

31

to 2

31

−1

OL

62

Pulse Position When Power is OFF (Lower 2
words)

pulse

0

-2

31

to 2

31

−1

OL

64

Pulse Position When Power is OFF (Upper 2
words)

pulse

0

-2

31

to 2

31

−1

No.

Name

Setting Unit

Default

Value

Setting Range