beautypg.com

Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual

Page 399

background image

10.4 Motion Parameter Details

10.4.2 Setting Parameter List

10-35

Settings for Connecting Inverters

OW

76

Transmission Reference Output Data 6

Setting range: 0 to FFFFH

This will be sent as the 7th word of the command Trans-
mission Reference.

OW

77

Transmission Reference Output Data 7

Setting range: 0 to FFFFH

This will be sent as the 8th word of the command Trans-
mission Reference.

OW

78

Transmission Reference Output Data 8

Setting range: 0 to FFFFH

This will be sent as the 1st word of the subcommand
Transmission Reference.

OW

79

Transmission Reference Output Data 9

Setting range: 0 to FFFFH

This will be sent as the 2nd word of the subcommand
Transmission Reference.

OW

7A

Transmission Reference Output Data 10

Setting range: 0 to FFFFH

This will be sent as the 3rd word of the subcommand
Transmission Reference.

OW

7B

Transmission Reference Output Data 11

Setting range: 0 to FFFFH

This will be sent as the 4th word of the subcommand
Transmission Reference.

OW

7C

Transmission Reference Output Data 12

Setting range: 0 to FFFFH

This will be sent as the 5th word of the sub command
Transmission Reference.

OW

7D

Transmission Reference Output Data 13

Setting range: 0 to FFFFH

This will be sent as the 6th word of the subcommand
Transmission Reference.

OW

7E

Transmission Reference Output Data 14

Setting range: 0 to FFFFH

This will be sent as the 7th word of the subcommand
Transmission Reference.

OW

7F

Transmission Reference Output Data 15

Setting range: 0 to FFFFH

This will be sent as the 8th word of the subcommand
Transmission Reference.

Register No.

Name

Contents