3 command details, 1 ) no command, 2 ) inverter drive control – Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual
Page 379

10.3 Main Commands and Subcommands
10.3.3 Command Details
10-15
Settings for Connecting Inverters
10.3.3 Command Details
Each command and its parameters are described below.
( 1 ) No Command
Description
No command to be executed
Setting Parameters
Monitoring Parameters
( 2 ) Inverter Drive Control
Description
Sends commands to the Inverter and monitors the Inverter.
If the command Inverter Drive Control is switched to another command during its execution, the Inverter retains the
last data and continues operation. The MPE720 retains the last data of the monitoring parameters since inputs and
outputs between SVB Module and Inverter are stopped. The monitoring parameter Status, however, will be updated
for any command being executed except Transmission Reference.
Setting Parameters
Name
Register No.
Setting Range
Remarks
Command Code
OW
08
0 to 8
00: No Command
Name
Register No.
Setting
Range
Remarks
Command Response Code
IW
08
0 to 8
00: No Command
Command Status
IW
09
Bit
Bit 0 (Command execution flag)
Always OFF
Bit 3 (Command error completed
status)
On when an error
occurs during command
processing.
Bit 8 (Command execution com-
pleted status)
ON when command
execution is completed.
Status
IW
10
Bit
Inverter status
Response Alarm Code
IW
30
0 to FFFFH
Inverter alarm code
Name
Register No.
Setting Range
Remarks
Command Code
OW
08
0 to 8
01: Inverter Drive Control
Output Data Option Selection
OW
0C
Bit 0 to 3
Input Data Option Selection
OW
0D
Bit 0 to C
Input Command
OW
10
Bit
Frequency Reference
OW
11
Torque Reference
OW
12
Torque Compensation
OW
13
Valid when the Output Data Option Selection
(OW
0C), bit 0 is ON.
Multi-function Analog Output
FM (Option)
OW
14
Valid when the Output Data Option Selection
(OW
0C), bit 1 is ON.
Multi-function Analog Output
AM (Option)
OW
15
Valid when the Output Data Option Selection
(OW
0C), bit 2 is ON.
Multi-function Terminal
Output
OW
16
Valid when the Output Data Option Selection
(OW
0C), bit 3 is ON.