beautypg.com

Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual

Page 437

background image

11.6 Parameters That Are Automatically Updated

11.6.2 Parameters Updated when a MECHATROLINK Connection Is Established (2) (Regardless of the User Constants Self-writing Func-
tion)

11-22

11.6.2 Parameters Updated when a MECHATROLINK Connection Is Established (2)

(Regardless of the User Constants Self-writing Function)

The Machine Controller parameter settings in the left table below are automatically written to the SERVOPACK
parameters given in the right table below when a connection is established between the Machine Controller and the
SERVOPACK. The parameters are written regardless of whether User Constants Self-writing Function is enabled or
disabled at bit A of fixed parameter 1 in the Machine Controller.

11.6.3 Parameters Updated when a Setting Parameter Is Changed

(MECHATROLINK-II Operating at 10 Mbps in 32-byte Mode with User Con-

stants Self-writing Function Enabled)

When User Constants Self-writing Function is enabled at bit A of fixed parameter 1 in the Machine Controller, the
parameters shown in the right table below are automatically updated every time the Machine Controller setting param-
eters in the left table below are updated. Updating occurs on all SERVOPACKs connected to a MECHATROLINK-II
operating at 10 Mbps in 32-byte mode.

* 1. When Pn833.0 is set to 0, Pn80B will be updated. When Pn833.0 is set to 1, Pn836 will be updated.
* 2. When Pn833.0 is set to 0, Pn80E will be updated. When Pn833.0 is set to 1, Pn83C will be updated.

MP2000 Series Machine Controller

SERVOPACK Parameter

Remarks

SGD-N, SGDB-N NS100

NS115

SGDS

SGDV

Fixed
parameters

No.16: Backlash Com-
pensation Amount

Pn81B

Pn214

Fixed
values

65535

Cn-001E

Position Error Overflow Range

32767

Pn505

Overflow Level

2

30

-1

Pn520

Excessive Position Error
Alarm Level

100

Pn51E

Excessive Position Error
Warning Level

Pn820 and Pn822 are
set to the same value.

Pn820 -

> Pn822

Processing to disable the latch
zone

0010H

Pn813

Monitor Options 1 or 2

0002H

Pn003

Pn824

Processing to monitor Torque/
Thrust Reference.

MP2000 Series Machine Controller

SERVOPACK

Remarks

SGD-N,

SGDB-N

NS100 NS115 SGDS SGDV

Setting
parameters

Width of Positioning
Completion

OL

1E

Pn500

Pn522

Position Loop Gain

OW

2E →

Pn102

Speed Loop Gain

OW

2F →

Pn100

Speed Feed Forward
Amends

OW

30

Pn109

Position Integration
Time Constant

OW

32

Pn11F

Speed Integration Time
Constant

OW

34

Pn101

Straight Line Accelera-
tion/Acceleration Time
Constant

OL

36

Pn80B

Pn80B/

Pn836

*1

Straight Line Decelera-
tion/Deceleration Time
Constant

OL

38

Pn80E

Pn80E/

Pn83C

*2