beautypg.com

5 speed reference – Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual

Page 156

background image

5.1 Example Setting of Motion Parameters for the Machine

5.1.5 Speed Reference

5-9

Motion Parameter Setting Examples

5.1.5 Speed Reference

There are two methods of setting the speed reference for the feed speed or other speeds. One method involves using
reference units and the other method involves setting the percentage (%) of the rated speed.
The following table shows the parameters relating to speed references.

Parameter Type

Parameter No.

(Register No.)

Name

Description

Default

Value

Motion Fixed
Parameters

No. 5

Number of
Digits below
Decimal Point

Set the number of digits below the decimal point in the refer-
ence unit being input. The minimum reference unit is deter-
mined by this parameter and the Reference Unit Selection
(fixed parameter 4).
Example:
Reference Unit Selection = mm, Number of Digits below
Decimal Point = 3
1 reference unit = 0.001 mm

3

No. 34

Rated Motor
Speed

Set the number of rotations when the motor is rotated at the
rated speed (100% speed). Confirm the motor specifications
before setting this parameter.

3000

No. 36

Number of
Pulses per
Motor Rotation

Set the number of pulses (the value after multiplication) per
motor rotation.
Example:
For a 16-bit encoder, set 2

16

= 65536.

65536

Motion Setting
Parameters

OW

03

Bits 0 to 3

Speed Unit
Selection

Set the unit for reference speeds.
0: Reference unit/s
1:10

n

reference units/min (n: Number of Digits below

Decimal Point)

2: 0.01%
3: 0.0001%

1

OL

10

Speed
Reference
Setting

Set the feed speed. The unit for this parameter is set in
OW

03, bits 0 to 3.

Example:
When the Number of Digits below Decimal Point is set to 3,
units are as follows for the setting of the Speed Unit:

• Speed Unit Set to 0: Reference units/s

pulse unit: 1 = 1 pulse/s
mm unit: 1 = 0.001 mm/s
deg unit: 1 = 0.001 deg/s
inch unit: 1 = 0.001 inch/s

μm unit: 1 = 0.001 μm/s

• Speed Unit Set to 1: 10

n

reference units/min

pulse unit: 1 = 1000 pulse/min
mm unit: 1 = 1 mm/min
deg unit: 1 = 1 deg/min
inch unit: 1 = 1 inch/min

μm unit: 1 = 1 μm/s

• Speed Unit Set to 2: 0.01%

Set as a percentage of the rated speed (1 = 0.01%) unre-
lated to the reference unit setting.

3000

OW

18

Override

Setting an output ratio (%) for the setting allows the posi-
tioning speed to be changed without changing the Speed Ref-
erence setting.
Setting unit: 1 = 0.01%

10000

R

R

R

R

R