6.2 Motion Command Details

6.2.25 Change Position Loop Integral Time Constant (KIS)

6-93

Motion Commands

6.2.25 Change Position Loop Integral Time Constant (KIS)

The KIS command transfers the setting of the Position Integration Time Constant (motion setting parameter
OW

32) to the Position Integration Time Constant in the SERVOPACK and enables the setting.

MECHATROLINK-II has a function that automatically updates setting parameters if a parameter changes. There is
no need to execute the KIS command with this function. For details, refer to bit A (User Constants Self-writing Func-
tion) in 4.4.1 ( 2 ) Function Selection 1.

( 1 ) Executing/Operating Procedure

1.

Check to see if all the following conditions are satisfied.

2.

Set OW

08 to 26 to execute the KIS motion command.

The KIS command will transfer the setting of the Position Integration Time Constant (motion setting parameter
OW

32) to the Position Integration Time Constant in the SERVOPACK and enables the setting.

IW

08 will be 26 during command execution.

IW

09, bit 0 will turn ON during the command processing and will turn OFF when the command processing

has been completed.

3.

Set OW

08 to 0 to execute the NOP motion command and then complete the change of the position

loop integration time.

( 2 ) Holding and Aborting

The Holds a Command bit (OW

09, bit 0) and the Interrupt a Command bit (OW

09, bit 1) cannot be used.

When the tuning-less function of the SGDV SERVOPACK is enabled or when the SERVOPACK parameter Pn170.0 is
set to 1 (Tuning-less Function Selection is enabled), these settings are disabled and ignored.

( 3 ) Related Parameters

[ a ] Setting Parameters

[ b ] Monitoring Parameters

No.

Execution Conditions

Confirmation Method

1

There are no alarms.

Both IL

02 and IL

04 are 0.

2

Motion command execution has been completed.

IW

08 is 0 and IW

09 bit0 is OFF.

Parameter

Name

Setting

OW

08

Motion Command

The feed forward is changed when this parameter is set to 26.

OW

09

Bit 0

Holds a Command

This parameter is ignored for KIS command.

OW

09

Bit 1

Interrupt a Command

This parameter is ignored for KIS command.

OW

32

Position Integration
Time Constant

Set the integration time constant for the position loop in milliseconds.

Parameter

Name

Monitor Contents

IL

02

Warning

Stores the most current warning.

IL

04

Alarm

Stores the most current alarm.

IW

08

Motion Command Re-
sponse Cable

Indicates the motion command that is being executed.
The response code will be 26 during KIS command execution.

IW

09

Bit 0

Command Execution
Flag

Turns ON during KIS command execution and turns OFF when execution has been
completed.

IW

09

Bit 1

Command Hold
Completed

Always OFF for KIS command.

IW

09

Bit 3

Command Error
Completed Status

Turns ON if an error occurs during KIS command execution.
Turns OFF when another command is executed.