12.3 Motion Program Alarms
12.3.1 Motion Program Alarm Configuration
12-27
Troubleshooting
12.3 Motion Program Alarms
If the result of investigation using 12.1.2 MP2000 Series Machine Controller Error Check Flowchart indicates that a
motion program alarm has occurred, use the alarm code to determine the cause of the error.
12.3.1 Motion Program Alarm Configuration
Motion program alarms stored in the alarm output register (default: SW03268) are displayed as shown in the following
diagram.
Refer to the relevant Machine Controller user’s manual for information on finding the alarm output register.
12.3.2 Motion Program Alarm Code List
The motion program alarm codes are listed in the following table.
When displaying these on the register list, set the view mode to hexadecimal.
* The axis number is stored in bits 8 to 12 for axis alarms.
Alarm axis information (1 to 16)
Bit 15
Bit 12
Bit 8 Bit 7
Bit 0
Alarm code (Axis alarm when bit 7 turns ON.)
Alarm Code
Description
Correction
Program
alarms
0
No alarm
Check the specifica-
tions for the instruc-
tion that was being
executed in the motion
program when the
alarm occurred accord-
ing to the meaning of
the alarm code.
10h
Complete circle specified for radius designation
11h
Interpolation feed speed exceeded
12h
Interpolation feed speed not specified
13h
Range exceeded after acceleration/deceleration speed parameter conversion
14h
LONG_MAX exceeded for circular arc length
15h
No vertical specification for circular plane designation
16h
No horizontal specification for circular plane designation
17h
Specified axes exceeded
18h
Specified number of turns exceeded
19h
LONG_MAX exceeded for radius
1Bh
Emergency stop in progress
1Ch
LONG_MAX exceeded for linear interpolation block moving amount
1Dh
FMX not defined
1Eh
Address T out of range
1Fh
Address P out of range
20h
REG data error
21h
Function work duplication (Function work in second PFORK column was
used at a different nesting level.)
22h
Indirect register designation range error
23h
Overflow when converting reference unit
Axis
alarms*
80h
During use of logical axis prohibited
81h
Specifications exceeding POSMAX made for infinite length axis designation
82h
LONG_MAX exceeded for axis moving distance
84h
Motion command duplication
85h
Motion command response duplication
87h
VEL setting data out of range
88h
INP setting data out of range
89h
ACC/SCC/DCC setting data out of range
8Ah
T reference for MVT instruction is 0
8Bh
Instruction designated that cannot be executed for the Motion Module model
8Ch
Prohibition command executed when pulse distribution was not completed
8Dh
Motion command error occurrence status