beautypg.com

8 ) bit 8: excessive speed, 9 ) bit 9: excessive deviation – Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual

Page 479

background image

12.5 Troubleshooting Motion Errors

12.5.2 Motion Error Details and Corrections

12-36

( 8 ) Bit 8: Excessive Speed

The maximum value for speed that can be specified is as follows, depending on the connected SERVOPACK.
In simulation mode, the maximum value for the speed is always 32767000 for all SERVOPACK models.

( 9 ) Bit 9: Excessive Deviation

The above check is not performed if the Error Count Alarm Detection (OL

22) is set to 0.

Detection Timing

• A move command is executed.

Processing when
Alarm Occurs

• The move command is not executed.
• The Command Error Completed Status in the Motion Command Status (IW

09, bit 3) will turn ON.

Error and Cause

• The speed (movement output for one scan in case of interpolation) commanded to MECHATROLINK

servo exceeds the upper limit.

Correction

• Check the settings for speed reference, interpolation command movement per scan, and speed compensa-

tion.

Model

Details

Maximum Value for Speed (Pulse/s)

SGD-

N

SGDB-

AN

MECHATROLINK-I-compatible
AC SERVOPACK

16384000

SGDH-

E

JUSP-NS100

SGDH SERVOPACK
NS100 MECHATROLINK-I
Application Module

131068000

SGDH-

E

JUSP-NS115

SGDH SERVOPACK
NS115 MECHATROLINK-II
Application Module

32767000

SGDS-

1

SGDS SERVOPACK

1048576000

SGDX-

12

SGDX SERVOPACK

1048576000

SGDV-

1

SGDV SERVOPACK

2097152000

SJDE-

AN

SJDE SERVOPACK

1048576000

Detection Timing

• Always, except during speed control and torque control

Processing when
Alarm Occurs

• The move command is not executed.
• The Command Error Completed Status in the Motion Command Status (IW

09, bit 3) will turn ON.

Error and Cause

One of the following is possible.

• The position loop gain and speed loop gain are not set correctly, creating poor response.
• The Error Count Alarm Detection (OL

22) is too small.

• The capacity of the motor is insufficient for the machine load.
• SERVOPACK failure

Correction

Check the following and correct the problem. If the problem persists, contact the maintenance department.

• Check the position loop gain and speed loop gain.
• Check the Error Count Alarm Detection (OL

22).

• Check the motor capacity.