beautypg.com

3 ) read user constant – Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual

Page 387

background image

10.3 Main Commands and Subcommands

10.3.4 Subcommand Details

10-23

Settings for Connecting Inverters

( 3 ) Read User Constant

Description

Reads the specified inverter user constant from the Inverter.

Valid only in MECHATROLINK-II 32-byte mode.

Setting Parameters

Monitoring Parameters

Name

Register No.

Setting Range

Remarks

Subcommand Code

OW

0A

0 to 9

02: Read User Constant

Auxiliary Inverter Constant Number

OW

42

0 to FFFFH

Auxiliary Inverter Constant Number
Size

OW

43

1 to 4

Data type: Word (Enter the size of user con-
stant that read out from the leading user con-
stant number of the auxiliary inverter.)

Name

Register No.

Setting

Range

Remarks

Subcommand Response Code

IW

0A

0 to 9

02: Read User Constant

Subcommand Status

IW

0B

Bit

Bit 0 (Command execution flag)

ON during execu-
tion

Bit 3 (Command error completed
status)

ON when an error
occurs during com-
mand processing.

Bit 8 (Command execution com-
pleted)

ON when command
execution is com-
pleted.

Subcommand Response Status

IW

31

Bit

Refer to Subcommand Response Status of 10.4.3 Moni-
toring Parameter List
.

Auxiliary Inverter User Constant
Number

IW

42

0 to FFFFH

Auxiliary User Constant
Reading Data 1

IW

44

0 to 65535

Auxiliary User Constant
Reading Data 2

IW

45

0 to 65535

Auxiliary User Constant
Reading Data 3

IW

46

0 to 65535

Auxiliary User Constant
Reading Data 4

IW

47

0 to 65535