6.2 Motion Command Details
6.2.27 Multiturn Limit Setting (MLTTRN_SET)
6-97
Motion Commands
6.2.27 Multiturn Limit Setting (MLTTRN_SET)
On executing the MLTTRN_SET command, the SERVOPACK auxiliary function Fn013 “multiturn limit setting”
*
is
automatically executed via MECHATROLINK. Execute this command when the SERVOPACK alarm “A.CC0 Multi-
turm Limit Mismatch” has occurred.
The MLTTRN_SET command is valid for
Σ-II, Σ-III, and Σ-V Series SERVOPACKs with an absolute encoder.
The command is completed in an error status if the MLTTRN_SET command is executed when an incremental
encoder is being used (or even if an absolute encoder is being used in the incremental encoder mode) with
Σ-II, Σ-
III, and
Σ-V Series SERVOPACKs.
* Fn013 “multiturn limit setting” is a function that matches the value of SERVOPACK parameter Pn205 “multiturn limit”
with the multiturn limit of the absolute encoder.
For more information, refer to the manual for the SERVOPACK that you are using.
( 1 ) Compatible Versions
The firmware and engineering tool versions that allow multiturn limit setting to be used with MP2000 series SVB mod-
ules are shown in the table below.
The table below indicates whether or not the function can be executed depending on the combination of the versions of
the MP2000 series SVB module and MPE720.
Controller
Model
Version
MP2100
JAPMC-MC2100 (-E)
Version 2.73 or later
MP2100M
JAPMC-MC2140 (-E)
MP2300
JEPMC-MP2300 (-E)
MP2300S
JEPMC-MP2300S-E
MP2310
JEPMC-MP2310-E
MP2400
JEPMC-MP2400-E
MP2000 series SVB-01 module
JAPMC-MC2310 (-E)
Version 1.27 or later
Engineering Tool
Model
Version
MPE720
CPMC-MPE720
Version 5.53 or later
MPE720 Version 6
CPMC-MPE770
Version 6.23 or later
MPE720 Version 7
CPMC-MPE780
Version 7.10 or later
Version
MPE720
Version 5.52, Version 6.22 or earlier
Version 5.53, Version 6.23 or later
C
ontrolle
r
MP2000 series Version 2.72,
SVB-01 module Version 1.26 or ear-
lier
• Cannot be executed.
• IL
02, bit 4 “Motion Command Set
Error” = ON
• Cannot be executed.
• IL
02, bit 4 “Motion Command Set
Error” = ON
MP2000 Version 2.73,
SVB-01 module Version 1.27 or later
• Can be executed.
(However, motion commands are not
displayed in the module configura-
tion.)
• Can be executed.