9 ) transmission reference – Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual
Page 384

10.3 Main Commands and Subcommands
10.3.3 Command Details
10-20
Monitoring Parameters
( 9 ) Transmission Reference
Description
Enables the user to freely set a command and send it through the transmission line.
Setting Parameters
Monitoring Parameters
Name
Register No.
Setting
Range
Remarks
Command Response Code
IW
08
0 to 8
07: User Constant EEPROM Writing
Command Status
IW
09
Bit
Bit 0 (Command execution flag)
ON during execution
Bit 3 (Command error completed
status)
ON when an error
occurs during com-
mand processing
Bit 8 (Command execution com-
pleted)
ON when command
execution is com-
pleted.
Status
IW
10
Bit
Inverter status
Response Alarm Code
IW
30
0 to FFFFH
Inverter alarm code
Name
Register No.
Setting Range
Remarks
Command Code
OW
08
0 to 8
08: Transmission Reference
Transmission Reference
Output Data 0
OW
70
0 to FFFFH
Command code on Lo (lower) bytes
.
.
.
.
.
.
0 to FFFFH
Transmission Reference
Output Data 7
OW
77
0 to FFFFH
The system implements watchdog timeout timer.
Name
Register No.
Setting
Range
Remarks
Command Response Code
IW
08
0 to 8
08: Transmission Reference
Command Status
IW
09
Bit
Bit 0 (Command execution flag)
ON during execution
Bit 3 (Command error completed
status)
Always OFF
Bit 8 (Command execution com-
pleted)
Always OFF
Transmission Reference Input
Data 0
IW
70
0 to FFFFH
Command code on Lo (lower) bytes, Alarm on Hi (upper)
bytes
.
.
.
.
.
.
0 to FFFFH
Transmission Reference Input
Data 7
IW
77
0 to FFFFH
The system implements watchdog timeout timer.