beautypg.com

4 ) timing charts, B ] monitoring parameters, A ] normal end [ b ] error end – Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual

Page 220

background image

6.2 Motion Command Details

6.2.11 Change Filter Time Constant (SCC)

6-59

Motion Commands

[ b ] Monitoring Parameters

( 4 ) Timing Charts

[ a ] Normal End

[ b ] Error End

Parameter

Name

Monitor Contents

IL

02

Warning

Stores the most current warning.

IL

04

Alarm

Stores the most current alarm.

IW

08

Motion Command
Response Code

Indicates the motion command that is being executed.
The response code is 12 during SCC command execution.

IW

09

Bit 0

Command Execution Flag

Turns ON during SCC command execution and turns OFF when execution has
been completed.

IW

09

Bit 1

Command Hold Completed

Always OFF for SCC command.

IW

09

Bit 3

Command Error Completed
Status

Turns ON if an error occurs during SCC command execution.
Turns OFF when another command is executed.

IW

09

Bit 8

Command Execution
Completed

Turns ON when SCC command execution has been completed.

OW

08 = 12 (SCC)

IW

08 = 12 (SCC)

IW

09, bit 0 (BUSY)

IW

09, bit 8 (COMPLETE)

IW

09, bit 3 (FAIL)

Undefined length

of time

OW

08 = 12 (SCC)

IW

08 = 12 (SCC)

IW

09, bit 0 (BUSY)

IW

09, bit 8 (COMPLETE)

IW

09, bit 3 (FAIL)

Undefined length

of time