beautypg.com

3 motion parameter lists, 1 fixed parameter list – Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual

Page 82

background image

4.3 Motion Parameter Lists

4.3.1 Fixed Parameter List

4-6

4.3 Motion Parameter Lists

4.3.1 Fixed Parameter List

The following table provides a list of SVB and SVR motion fixed parameters.

Refer to the section numbers indicated in the Reference column for details of each fixed parameter.
For information on SVR, refer to 1.3 SVR Virtual Motion Module.

No.

Name

Contents

SVB SVR

Reference

0

Selection of Operation Modes

0: Normal Operation Mode

Yes

Yes

4.4.1 ( 1 )

1: Axis unused

Yes

Yes

2: Simulation mode

Yes

3: Servo Driver Transmission Reference Mode

Yes

4 and 5: Reserved for system use.

1

Function Selection Flag 1

Bit 0: Axis Selection (0: Finite length axis/1: Infinite length axis)

Set to 0 for linear type.

Yes

Yes

4.4.1 ( 2 )

Bit 1: Soft Limit (Positive Direction) Enable/Disable
(0: Disabled/1: Enabled)

Yes

Bit 2: Soft Limit (Negative Direction) Enable/Disable
(0: Disabled/1: Enabled)

Yes

Bit 3: Overtravel Positive Direction Enable/Disable
(0: Disabled/1: Enabled)

Yes

Bit 4: Overtravel Negative Direction Enable/Disable
(0: Disabled/1: Enabled)

Yes

Bits 5 to 7: Reserved for system use.

Bit 8: Interpolation Segment Distribution Processing

Yes

Bit 9: Simple ABS Rotary Pos. Mode (Simple absolute infinite axis
position control) (0: Disabled/1: Enabled)

Set to 0 for linear type.

Yes

Bit A: User Constants Self-writing Function

Yes

Bits B to F: Reserved for system use.

2

Function Selection Flag 2

Bit 0: Communication Abnormality Detection Mask

Yes

4.4.1 ( 3 )

Bit 1: WDT Abnormality Detection Mask

Yes

Bits 2 to F: Reserved for system use.

3

Reserved for system use.

4

Reference Unit Selection

0: pulse

3: inch

1: mm

4:

μm

2: deg

For linear type, 0 (pulse), 1 (mm), and 4 (

μm) can be

used. If 2 (deg.) or 3 (inch) is selected, the selected unit
will be converted to mm.

Yes

Yes

4.4.1 ( 4 )

5

Number of Digits below Deci-
mal Point

1 = 1 digit

Yes

Yes

6

Travel Distance per Machine
Rotation
(rotary motor)

1 = 1 user unit

Yes

Yes

Linear Scale Pitch
(linear motor)

1 = 1 user unit

Yes

Yes

8

Servo Motor Gear Ratio

1 = 1 rev

Invalid for linear type

Yes

Yes

9

Machine Gear Ratio

1 = 1 rev

Invalid for linear type

Yes

Yes

10

Infinite Length Axis Reset Po-
sition (POSMAX)

1 = 1 user unit

Invalid for linear type

Yes

Yes

4.4.1 ( 5 )

12

Positive Software Limit Value

1 = 1 user unit

Yes

4.4.1 ( 6 )

14

Negative Software Limit Value 1 = 1 user unit

Yes

16

Backlash Compensation
Amount

1 = 1 user unit

Yes

4.4.1 ( 7 )