4.3 Motion Parameter Lists
4.3.1 Fixed Parameter List
4-6
4.3 Motion Parameter Lists
4.3.1 Fixed Parameter List
The following table provides a list of SVB and SVR motion fixed parameters.
Refer to the section numbers indicated in the Reference column for details of each fixed parameter.
For information on SVR, refer to 1.3 SVR Virtual Motion Module.
No.
Name
Contents
SVB SVR
Reference
0
Selection of Operation Modes
0: Normal Operation Mode
Yes
Yes
4.4.1 ( 1 )
1: Axis unused
Yes
Yes
2: Simulation mode
Yes
−
3: Servo Driver Transmission Reference Mode
Yes
−
4 and 5: Reserved for system use.
−
−
1
Function Selection Flag 1
Bit 0: Axis Selection (0: Finite length axis/1: Infinite length axis)
Set to 0 for linear type.
Yes
Yes
4.4.1 ( 2 )
Bit 1: Soft Limit (Positive Direction) Enable/Disable
(0: Disabled/1: Enabled)
Yes
−
Bit 2: Soft Limit (Negative Direction) Enable/Disable
(0: Disabled/1: Enabled)
Yes
−
Bit 3: Overtravel Positive Direction Enable/Disable
(0: Disabled/1: Enabled)
Yes
−
Bit 4: Overtravel Negative Direction Enable/Disable
(0: Disabled/1: Enabled)
Yes
−
Bits 5 to 7: Reserved for system use.
−
−
Bit 8: Interpolation Segment Distribution Processing
Yes
−
Bit 9: Simple ABS Rotary Pos. Mode (Simple absolute infinite axis
position control) (0: Disabled/1: Enabled)
Set to 0 for linear type.
Yes
−
Bit A: User Constants Self-writing Function
Yes
−
Bits B to F: Reserved for system use.
−
−
2
Function Selection Flag 2
Bit 0: Communication Abnormality Detection Mask
Yes
−
4.4.1 ( 3 )
Bit 1: WDT Abnormality Detection Mask
Yes
−
Bits 2 to F: Reserved for system use.
−
−
3
−
Reserved for system use.
−
−
−
4
Reference Unit Selection
0: pulse
3: inch
1: mm
4:
μm
2: deg
For linear type, 0 (pulse), 1 (mm), and 4 (
μm) can be
used. If 2 (deg.) or 3 (inch) is selected, the selected unit
will be converted to mm.
Yes
Yes
4.4.1 ( 4 )
5
Number of Digits below Deci-
mal Point
1 = 1 digit
Yes
Yes
6
Travel Distance per Machine
Rotation
(rotary motor)
1 = 1 user unit
Yes
Yes
Linear Scale Pitch
(linear motor)
1 = 1 user unit
Yes
Yes
8
Servo Motor Gear Ratio
1 = 1 rev
Invalid for linear type
Yes
Yes
9
Machine Gear Ratio
1 = 1 rev
Invalid for linear type
Yes
Yes
10
Infinite Length Axis Reset Po-
sition (POSMAX)
1 = 1 user unit
Invalid for linear type
Yes
Yes
4.4.1 ( 5 )
12
Positive Software Limit Value
1 = 1 user unit
Yes
−
4.4.1 ( 6 )
14
Negative Software Limit Value 1 = 1 user unit
Yes
−
16
Backlash Compensation
Amount
1 = 1 user unit
Yes
−
4.4.1 ( 7 )