beautypg.com

Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual

Page 296

background image

7.2 Motions After Switching Motion Commands

7.2.7 Switching from STEP

7-26

STEP

ZRET

STEP will immediately switch to ZRET, and the moving amount stored in the accelera-
tion/deceleration filter will be maintained.

INTERPOLATE

STEP will switch to INTERPOLATE when the axis stops after deceleration.

1C) during Deceleration>

• In Incremental Addition Mode (OW

09, bit 5 = 0)

Any change in the Position Reference Setting (OL

1C) will be ignored.

• In Absolute Mode (OW

09, bit 5 = 1)

The change in the Position Reference Setting (OL

1C) will be output as soon as the

first high-speed scan after INTERPOLATE execution starts.

Do not change the Position Reference Setting during deceleration unless it is
absolutely necessary.

ENDOF_INTER

POLATE

Same as INTERPOLATE

LATCH

Same as for INTERPOLATE

FEED

STEP will immediately switch to FEED, and the moving amount stored in the accelera-
tion/deceleration filter will be maintained.

STEP

STEP operation will continue.

Switched From

Switched To

Operation

STEP

Cancelled STEP

operation

STEP

ZRET

STEP

ZRET

The speed will smoothly change.

(The speed at the time the motion com-

mand is switched will increase/decrease

until it reaches the target speed of ZRET.)

The acceleration/deceleration filter will

remain valid.

ZRET

Motion command
Motion command

response

STEP

Cancelled STEP
operation

STEP

INTERPOLATE

STEP

INTERPOLATE

INTERPOLATE

Motion command

Motion command

response

STEP

STEP

FEED

STEP

FEED

The speed will smoothly change.

(The speed at the time the motion com-

mand is switched will increase/decrease

until it reaches the target speed of FEED.)

The acceleration/deceleration filter will

remain valid.

FEED

Motion command
Motion command

response