2 ) parameter settings – Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual
Page 419

11.1 Controlling Vertical Axes
11.1.2 Connections to
Σ-II/III SGDH or SGDS SERVOPACK
11-4
( 2 ) Parameter Settings
The SERVOPACK parameters related to control the holding brake are described below.
Parameter
Name
Unit
Setting/Range
Default
Control Mode
Pn50F.2
Output Signal Selection 2
−
0: Brake not used
1: Terminal numbers 1 and 2
2: Terminal numbers 23 and 24
3: Terminal numbers 25 and 26
1
Speed, torque,
position control
Details
The following parameter determines which CN1 pin (0 to 3 above) will be used to output the /BK signal.
Parameter
Name
Unit
Setting/Range
Default
Control Mode
Pn506
Brake ON Timing after Motor Stops
10 ms
0 to 50
0
Speed, torque,
position control
Details
This parameter adjusts the delay time from /BK Signal Output until Servo OFF (stopping Servomotor output), and
it is used to be set when the machine moves slightly due to gravity or other factors after turning the brake ON.
This parameter is used to set the timing when the motor is stopped. Brake operation while the motor
is running is set in Pn507 and Pn508.
For the standard settings, the Servo will turn OFF simultaneously with the /BK output (Brake Opera-
tion). If gravity causes the machine to move slightly at this time due to machine configuration or
brake characteristics, turning OFF the Servo can be delayed to reduce the movement.
Pn507
Brake ON Timing when Motor Run-
ning
min
−1
0 to 10000
100
Speed, torque,
position control
Pn508
10 ms
0 to 100
50
Speed, torque,
position control
Details
Pn507: Speed Level for BK Signal Output when Motor Running
Pn508: Timing of BK Signal Output when Motor Running
These settings are used to set the timing for applying the brake when the Servo turns OFF due to an /S-ON input signal or alarm.
Pn50F.2
1
2
3
Output Terminals
CN1-1, 2 (SO1)
CN1-23, 24 (SO2)
CN1-25, 26 (SO3)
/BK brake
interlock output
/S-ON input
/BK output
Servo ON
Motor ON
Brake holding
Servo OFF
Motor OFF
Pn506
Servo ON/OFF
operation (motor
ON status)
Brake
released
Servo OFF
delay time
Motor speed
Pn507
/BK output
Servo ON
Servo OFF
Pn508
Brake holding
/S-ON input or
alarm occurred.
Power OFF
Stop with dynamic
brake or by coasting
(Pn001.0)
Brake
released
The brake on the Servomotor is
designed as a holding brake and it
must be applied only after the motor
has stopped. Adjust this parameter
while observing machine operation.