7.2 Motions After Switching Motion Commands
7.2.7 Switching from STEP
7-25
Switching Commands during Execution
7.2.7 Switching from STEP
Switched From
Switched To
Operation
STEP
NOP
STEP will switch to NOP when the axis stops after deceleration.
POSING
STEP will immediately switch to POSING, and the moving amount stored in the accelera-
tion/deceleration filter will be maintained.
The value of the Position Reference Setting (OL
1C) when the motion command is
switched will be as follows.
09, bit 5 = 0)> Incremental value = Target position − IL 14 (DPOS) OL 1C = OL 1C+ Incremental value 09, bit 5 = 1)> OL 1C = Target position EX_POSING STEP will immediately switch to EX_POSING, and the moving amount stored in the The value of the Position Reference Setting (OL 1C) when the motion command is switched will be as follows. 09, bit 5 = 0)> Incremental value = Target position − IL 14 (DPOS) OL 1C = OL 1C+ Incremental value 09, bit 5 = 1)> OL 1C = Target position STEP STEP NOP STEP NOP Motion command Motion command response STEP STEP POSING STEP POSING The speed will smoothly change. (The speed at the time the motion command is switched will increase/decrease until it reaches the target speed of POSING.) The acceleration/deceleration filter will remain valid. POSING Motion command response STEP STEP EX_POSING STEP EX_POSING The speed will smoothly change. (The speed at the time the motion com- mand is switched will increase/decrease until it reaches the target speed of EX_POSING.) The acceleration/deceleration filter will remain valid. EX_POSING Motion command response
acceleration/deceleration filter will be maintained.
Motion command