beautypg.com

A-42 2 – Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual

Page 531

background image

Appendix I Servo Driver Transmission Reference Mode

I.5 Operation Procedure in Servo Driver Transmission Reference Mode

A-42

2.

First, enter the data for registers from OW

71 to OW

77. Then, set 001CH (PPRM_WR com-

mand) for OW

70 at the end.

Use the little-endian format to set the data.

3.

Display registers IW

70 to IW

77 in the Register List.

The response to the PPRM_WR command can be confirmed in registers IW

70 to IW

77 as shown below.

MECHATROLINK Command

Settings in Register List

Byte

Command

Set Value

Register

Set Value (HEX)

1

PPRM_WR

1CH

OW

70

001CH
(Enter at the end.)

2

0

3

0

OW

71

0

4

0

5

NO

02H

OW

72

0120H

6

01H

7

SIZE (byte)

2

OW

73

B402H

8

PARAMETER

B4H

9

0

OW

74

0

10

0

11

0

OW

75

0

12

0

13

0

OW

76

0

14

0

15

0

OW

77

0

16

WDT

0