4.4 MP2000 Series Machine Controller Parameter Details

4.4.2 Motion Setting Parameter Details

4-56

( 30 ) SERVOPACK Commands

( 31 ) Supplemental Settings

OW

4F

Servo Driver Alarm Monitor No.

Setting Range

Setting Unit

Default Value

0 to 10

0

Description

Set the number of the alarm to monitor.

Set the number of the alarm or warning to monitor for the ALM_MON or ALM_HIST motion command.
The result of monitoring will be stored as the Servo Driver Alarm Code (monitoring parameter IW

2D).

Refer to Chapter 6 Motion Commands for details.

OW

50

Servo Driver User Constant No.

Setting Range

Setting Unit

Default Value

0 to 65535

0

Description

Set the number of the SERVOPACK parameter.

Set the number of the SERVOPACK parameter to be processed for the PRM_RD, PRM_WR or PPRM_WR motion com-
mand.

Refer to Chapter 6 Motion Commands for details.

OW

51

Servo Driver User Constant Size

Setting Range

Setting Unit

Default Value

1, 2

1

Description

Set the number of words in the SERVOPACK parameter.

Set the number of words in the SERVOPACK parameter to be processed for the PRM_RD, PRM_WR or
PPRM_WRmotion command.

Refer to Chapter 6 Motion Commands for details.

OL

52

Servo Driver User Constant Set Point

Setting Range

Setting Unit

Default Value

−2

31

to 2

31

−1

0

Description

Set the setting for the SERVOPACK parameter.

Set the setting value to be written to the SERVOPACK parameter with the PRM_WR, PPRM_WR motion command.

Refer to Chapter 6 Motion Commands for details.

OW

54

Servo Driver for Assistance User Constant No.

Setting Range

Setting Unit

Default Value

0 to 65535

0

Description

Set the number of the SERVOPACK parameter.

Set the number of the SERVOPACK parameter to be processed for the PRM_RD or PRM_WR motion subcommand.

Refer to Chapter 6 Motion Commands for details.

OW

55

Servo Driver for Assistance User Constant Size

Setting Range

Setting Unit

Default Value

1, 2

1

Description

Set the number of words in the SERVOPACK parameter.

Set the number of words in the SERVOPACK parameter to be processed for the PRM_RD or PRM_WR motion subcom-
mand.

Refer to Chapter 6 Motion Commands for details.

OL

56

Servo Driver for Assistance User Constant Set Point

Setting Range

Setting Unit

Default Value

−2

31

to 2

31

−1

0

Description

Set the setting for the SERVOPACK parameter.

Set the setting value to be written to the SERVOPACK parameter with the PRM_WR motion subcommand.

Refer to Chapter 6 Motion Commands for details.

OW

5C

Fixed Parameter Number

Setting Range

Setting Unit

Default Value

0 to 65535

0

Description

Set the number of the fixed parameter to be read with the motion subcommand FIXPRM_RD.

The results of the Read Fixed Parameters operation are stored in the Fixed Parameter Monitor (monitoring parameter
IW

56).

For details, refer to 6.3 Motion Subcommands and 6.4 Motion Subcommand Details.

Position

Phase

Speed Torque

Position

Phase

Speed Torque

Position

Phase

Speed Torque

Position

Phase

Speed Torque

Position

Phase

Speed Torque

Position

Phase

Speed Torque

Position

Phase

Speed Torque

R

Position

Phase

Speed Torque