10.4 Motion Parameter Details
10.4.3 Monitoring Parameter List
10-39
Settings for Connecting Inverters
IW
0F
Auxiliary Input Data
Option Selection
Monitor
Bit 0: Motor Speed
ON when Motor Speed monitor is selected for Auxil-
iary Input Data Option Selection (OW
0F) and the
data is being normally updated.
Bit 1: Torque Reference
(U1-09)
ON when Torque Reference Monitor is selected for
Auxiliary Input Data Option Selection (OW
0F) and
the data is being normally updated.
Bit 2: Encoder Count
ON when Encoder Count monitor is selected for Auxil-
iary Input Data Option Selection (OW
0F) and the
data is being normally updated.
Bit 3: Frequency Reference
(U1-01)
ON when Frequency Reference monitor is selected for
Auxiliary Input Data Option Selection (OW
0F) and
the data is being normally updated.
Bit 4: Multi-function Analog
Input A2
ON when Multi-function Analog Input A2 monitor is
selected for Auxiliary Input Data Option Selection
(OW
0F) and the data is being normally updated.
Bit 5: Main Bus Voltage
ON when Main Bus Voltage monitor is selected for
Auxiliary Input Data Option Selection (OW
0F) and
the data is being normally updated.
Bit 6: Alarm Code
ON when Alarm Code monitor is selected for Auxiliary
Input Data Option Selection (OW
0F) and the data
is being normally updated.
Bit 7: Warning Code
ON when Warning Code monitor is selected for Auxil-
iary Input Data Option Selection (OW
0F) and the
data is being normally updated.
Bit 8
Reserved by the system
Bit 9: Multi-function Analog
Input A3
ON when Multi-function Analog Input A3 monitor is
selected for Auxiliary Input Data Option Selection
(OW
0F) and the data is being normally updated.
Bit A: Multi-function Input
Terminal
ON when Multi-function Input Terminal monitor is
selected for Auxiliary Input Data Option Selection
(OW
0F) and the data is being normally updated.
Bit B: Multi-function Analog
Input A1
ON when Multi-function Analog Input A1 monitor is
selected for Auxiliary Input Data Option Selection
(OW
0F) and the data is being normally updated.
Bit C: Encoder Counter
(ch2)
ON when Encoder Counter (ch2) monitor is selected for
Auxiliary Input Data Option Selection (OW
0F) and
the data is being normally updated.
Bits D to F
Reserved by the system
Register No.
Name
Contents