10.4 Motion Parameter Details

10.4.3 Monitoring Parameter List

10-39

Settings for Connecting Inverters

IW

0F

Auxiliary Input Data
Option Selection
Monitor

Bit 0: Motor Speed

ON when Motor Speed monitor is selected for Auxil-
iary Input Data Option Selection (OW

0F) and the

data is being normally updated.

Bit 1: Torque Reference
(U1-09)

ON when Torque Reference Monitor is selected for
Auxiliary Input Data Option Selection (OW

0F) and

the data is being normally updated.

Bit 2: Encoder Count

ON when Encoder Count monitor is selected for Auxil-
iary Input Data Option Selection (OW

0F) and the

data is being normally updated.

Bit 3: Frequency Reference
(U1-01)

ON when Frequency Reference monitor is selected for
Auxiliary Input Data Option Selection (OW

0F) and

the data is being normally updated.

Bit 4: Multi-function Analog
Input A2

ON when Multi-function Analog Input A2 monitor is
selected for Auxiliary Input Data Option Selection
(OW

0F) and the data is being normally updated.

Bit 5: Main Bus Voltage

ON when Main Bus Voltage monitor is selected for
Auxiliary Input Data Option Selection (OW

0F) and

the data is being normally updated.

Bit 6: Alarm Code

ON when Alarm Code monitor is selected for Auxiliary
Input Data Option Selection (OW

0F) and the data

is being normally updated.

Bit 7: Warning Code

ON when Warning Code monitor is selected for Auxil-
iary Input Data Option Selection (OW

0F) and the

data is being normally updated.

Bit 8

Reserved by the system

Bit 9: Multi-function Analog
Input A3

ON when Multi-function Analog Input A3 monitor is
selected for Auxiliary Input Data Option Selection
(OW

0F) and the data is being normally updated.

Bit A: Multi-function Input
Terminal

ON when Multi-function Input Terminal monitor is
selected for Auxiliary Input Data Option Selection
(OW

0F) and the data is being normally updated.

Bit B: Multi-function Analog
Input A1

ON when Multi-function Analog Input A1 monitor is
selected for Auxiliary Input Data Option Selection
(OW

0F) and the data is being normally updated.

Bit C: Encoder Counter
(ch2)

ON when Encoder Counter (ch2) monitor is selected for
Auxiliary Input Data Option Selection (OW

0F) and

the data is being normally updated.

Bits D to F

Reserved by the system

Register No.

Name

Contents