beautypg.com

4 ) timing charts – Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual

Page 214

background image

6.2 Motion Command Details

6.2.8 Set Zero Point (ZSET)

6-53

Motion Commands

[ b ] Monitoring Parameters

( 4 ) Timing Charts

[ a ] Normal Execution

Parameter

Name

Monitor Contents

SVR

IL

02

Warning

Stores the most current warning.

IL

04

Alarm

Stores the most current alarm.

IW

08

Motion Command Re-
sponse Code

Indicates the motion command that is being executed.
The response code will be 9 during ZSET command execution.

IW

09

Bit 0

Command Execution
Flag

Turns ON during ZSET command execution and turns OFF when ZSET com-
mand execution has been completed.

IW

09

Bit 1

Command Hold
Completed

Always OFF for ZSET command.

IW

09

Bit 3

Command Error
Completed Status

Turns ON if an error occurs during ZSET command execution.
Turns OFF when another command is executed.

IW

09

Bit 8

Command Execution
Completed

Turns ON when ZSET command execution has been completed.

IW

0C

Bit 5

Zero Point Return
(Setting) Completed

Turns ON when the setting of the zero point has been completed.

R

R

R

R

R

R

R

R

OW

08 = 9 (ZSET)

IW

08 = 9 (ZSET)

IW

09, bit 0 (BUSY)

IW

09, bit 8 (COMPLETE)

IW

0C, bit 5 (ZRNC)

IW

09, bit 3 (FAIL)