3.4 Self-configuration and Definition Files

3.4.4 Current Value and Setting Data in SVB

3-31

Self-configuration and Created Definition Files

( 6 ) Changing Parameters in the SERVOPACK Tab Page

The data flow for SERVOPACK parameters is as follows when parameters for the cursor position are changed from the
SERVOPACK Tab Page in the SVB Definition Window for MPE720:

• The MPE720 writes parameters of the relevant axis to the followings when the ENTER Key is pressed on the

computer. (The parameters other than those of the relevant axis will not be written.)

Input Data (set data) on the SERVOPACK Tab Page
• SDRAM of the Machine Controller
• RAM of the SERVOPACK

• After having completed writing, the MPE720 updates the values in Input Data on the SERVOPACK Tab Page

with the parameter values stored in the RAM of the SERVOPACK.

indicates data has been written.

MECHATROLINK

RAM

EEP

-ROM

SRAM

SDRAM

Input

Data

MPE720 㧔online㧕

HDD in personal computer

Display

Current

Value

Input

Data

Flash

Memory

SERVOPACK Parameters

(All Axes)

Parameters

System

Software

Control

Software

SERVOPACK

SERVOPACK

Send Send

Machine Controller