Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual
Page 38

2.2 Applicable Machine Controllers for SVB-01 Modules
2-7
Settings and Installation
* 1. One of the CPU modules indicated below is required.
* 2. Inter-rack connection module EXIOIF (Model: JAPMC-EX2200) is required between racks.
SVB-01 Modules cannot be mounted on the following MP2000-series Machine Controllers:
MP2100, MP2400, MP2500, MP2500M, MP2500B, MP2500MB
MP2500B-OP
JEPMC-MP250U
14 modules
Ver. 2.44
or later
Ver. 6.10
or later
To install an optional module, use the
following procedure.
The procedures differ if connecting one
module or several modules.
For one module
Mount an optional module on
MP2500B-OP or an MP2500MB-OP
controller directly.
For several modules
1. Mount an inter-rack connection
module EXIOIF (Model: JAPMC-
EX2200) on an MP2500B-OP or an
MP2500MB-OP controller.
2. Mount an optional module on an
expansion rack (MP2200 base unit).
3. Mount an inter-rack connection
module EXIOIF (Model: JAPMC-
EX2200) on the expansion rack.
4. Connect the expansion rack to the
MP2500B-OP or the MP2500MB-
OP controller.
The maximum number of optional
modules is the total number that
can be used with three racks
(maximum number of racks).
MP2500MB-OP
JEPMC-MP254U
(cont’d)
Name
Model
Max. Number
of SVB-01
Modules that
Can Be
Connected
Applicable
CPU
Version
Applicable
MPE720
Version
Remarks
Name
Model
Remarks
CPU-01
JAPMC-CP2200
–
CPU-02
JAPMC-CP2210
Equipped with one CF card slot and one USB port
CPU-03
JAPMC-CP2220-E
Equipped with one CF card slot and one Ethernet port.
CPU-04
JAPMC-CP2230-E
Equipped with one Ethernet port.