background image

2.2 Applicable Machine Controllers for SVB-01 Modules

2-7

Settings and Installation

* 1. One of the CPU modules indicated below is required.

* 2. Inter-rack connection module EXIOIF (Model: JAPMC-EX2200) is required between racks.

SVB-01 Modules cannot be mounted on the following MP2000-series Machine Controllers:
MP2100, MP2400, MP2500, MP2500M, MP2500B, MP2500MB

MP2500B-OP

JEPMC-MP250U

14 modules

Ver. 2.44
or later

Ver. 6.10
or later

To install an optional module, use the
following procedure.
The procedures differ if connecting one
module or several modules.

For one module

Mount an optional module on
MP2500B-OP or an MP2500MB-OP
controller directly.

For several modules

1. Mount an inter-rack connection

module EXIOIF (Model: JAPMC-
EX2200) on an MP2500B-OP or an
MP2500MB-OP controller.

2. Mount an optional module on an

expansion rack (MP2200 base unit).

3. Mount an inter-rack connection

module EXIOIF (Model: JAPMC-
EX2200) on the expansion rack.

4. Connect the expansion rack to the

MP2500B-OP or the MP2500MB-
OP controller.

The maximum number of optional
modules is the total number that
can be used with three racks
(maximum number of racks).

MP2500MB-OP

JEPMC-MP254U

(cont’d)

Name

Model

Max. Number

of SVB-01

Modules that

Can Be

Connected

Applicable

CPU

Version

Applicable

MPE720

Version

Remarks

Name

Model

Remarks

CPU-01

JAPMC-CP2200

CPU-02

JAPMC-CP2210

Equipped with one CF card slot and one USB port

CPU-03

JAPMC-CP2220-E

Equipped with one CF card slot and one Ethernet port.

CPU-04

JAPMC-CP2230-E

Equipped with one Ethernet port.