beautypg.com

29 ) servopack user monitor – Yaskawa MP2000 Series: Built-in SVB or SVB-01 Motion Module User Manual

Page 131

background image

4.4 MP2000 Series Machine Controller Parameter Details

4.4.2 Motion Setting Parameter Details

4-55

Motion Parameters

( 29 ) SERVOPACK User Monitor

OW

4E

Servo User Monitor Setting

Setting Range

Setting Unit

Default Value

0E00H

Description

Bit 4 to

Bit 7

Monitor 2

Monitor 2 is used with the MECHATROLINK-I and the MECHATROLINK-II in 17-byte Mode when bit 0
of OW

02 is 1.

0:Reference position in command coordinate system (reference unit)
1:Reference position in machine coordinate system (reference unit)
2:Following error (reference unit)
3:Feedback position in machine coordinate system (reference unit)
4:Feedback latch position in machine coordinate system (reference unit)
5:Reference position in command coordinate system (reference unit)
6:Target position in command coordinate system (reference unit)
7:
8:Feedback speed (position/torque control: reference units/s, speed control: maximum speed/40000000 hex)
9:Command speed (position/torque control: reference units/s, speed control: maximum speed/40000000

hex)

A:Target speed (position/torque control: reference units/s, speed control: maximum speed/40000000 hex)
B:Torque reference (position/speed control: reference units/s, torque control: maximum torque/40000000

hex)

C:
D:
E:Option Monitor 1 (default)
F:Option Monitor 2

(The information that can be monitored will differ depending on individual SERVOPACK specifications.
Refer to the relevant SERVOPACK user’s manual for details.)

Bit C to

Bit F

Monitor 4

Monitor 4 is used only with the MECHATROLINK-II in 32-byte Mode.
0 to F: Same as for Monitor 2.

Position

Phase

Speed Torque