Rebooting a brocade switch – Brocade Network OS NETCONF Operations Guide v4.1.1 User Manual
Page 59
![background image](/manuals/361608/59/background.png)
Network OS NETCONF Operations Guide
27
53-1003231-02
Rebooting a Brocade switch
3
•
Enable the chassis to bring the interfaces back online. All interfaces that passed POST are
enabled and come back online. If the switch was part of an Ethernet fabric, it rejoins the fabric.
NOTE
Disabling the chassis is a disruptive operation. Alternatively, you can shut down and re-enable
individual interfaces.
To enable a chassis, issue the
urn:brocade.com:mgmt:brocade-chassis namespace.
To re-enable a disabled chassis, issue the
urn:brocade.com:mgmt:brocade-chassis namespace.
rpc xmlns="urn:ietf:params:xml:ns:netconf:base:1.0" message-id="303">
Rebooting a Brocade switch
Network OS NETCONF interface provides the following methods to reboot your system: fastboot,
and ha chassisreboot.
•
Use the fastboot operation to reboot a compact chassis or just the management module of a
modular chassis. Power-on self-test (POST) is bypassed.
•
The ha chassisreboot operation performs a “cold reboot” (power off and restart) of the entire
modular chassis. If POST is enabled, POST is executed when the system comes back up.
CAUTION
Do not perform a reload operation between a disable operation and an enable operation on a
chassis. Your ports will be closed.