FRU monitoring

12

To set FRU state alerts and actions, perform the following steps.

1. Issue the RPC to configure the node in the

urn:brocade.com:mgmt:brocade-system-monitor namespace.

2. Under the node, include a node element for each FRU for which you want to

configure an alert state or alert action.

Node elements that can have their alert state and action set include , ,
, , and .

3. Under the node element designating the FRU, include the node element.

4. Under the node element, include the following leaf elements.

a. In the element, specify the state of the FRU for which you want the system to

generate an alert.

Valid values for , , , and include “removed,”
“inserted,” “on,” “faulty,” “none,” and “all.”

Valid values for include “removed,” “inserted,” “faulty,” “none,” and “all.”

b. In the element, specify the action to take place when the FRU transitions into the

state specified in the element.

Valid values include “none” (take no action), “email” (send and e-mail message), “raslog”
(issue a RASlog message), and “all” (send and e-mail message and issue a RASlog
message).

The following example issues a RASlog message if a fan, or power unit, or line card is removed, or
sends an e-mail message if the CID card is faulty or inserted.

removed

raslog

removed

raslog

inserted faulty

email

none

none