Fru monitoring, Setting system thresholds – Brocade Network OS NETCONF Operations Guide v4.1.1 User Manual
Page 176
144
Network OS NETCONF Operations Guide
53-1003231-02
FRU monitoring
12
System Monitor parameters are defined in the brocade-system-monitor,
brocade-system-monitor-ext, brocade-threshold-monitor, and brocade-threshold-monitor-ext YANG
modules. For an overview and structural map of the YANG modules, refer to the Network OS YANG
Reference Manual. For definitions and explanations of all user management parameters, refer to
the brocade-system-monitor.yang, brocade-system-monitor-ext.yang,
brocade-threshold-monitor.yang, and brocade-threshold-monitor-ext.yang files.
FRU monitoring
System Monitor monitors the absolute state of the fans, power supplies, CID card, line cards, and
SFPs. For a description of possible states, and hardware platform default threshold settings, refer
to the Network OS Administrator’s Guide.
Setting system thresholds
Each component can be in one of two states, down or marginal, based on factory-defined or
user-configured thresholds.
NOTE
You can disable monitoring of each component by setting the down threshold and the marginal
threshold to zero.
To set system threshold values, perform the following steps.
1. Issue the
urn:brocade.com:mgmt:brocade-system-monitor namespace.
2. Under the
configure the system thresholds.
Node elements that can have their system thresholds configured include
3. Under the node element designating the FRU, include the
4. Under the
a. In the
MARGINAL status of the switch.
b. In the
status of he switch.
The following example sets the MARGINAL and DOWN threshold values for each FRU type.