FRU monitoring

12

System Monitor parameters are defined in the brocade-system-monitor,
brocade-system-monitor-ext, brocade-threshold-monitor, and brocade-threshold-monitor-ext YANG
modules. For an overview and structural map of the YANG modules, refer to the Network OS YANG
Reference Manual
. For definitions and explanations of all user management parameters, refer to
the brocade-system-monitor.yang, brocade-system-monitor-ext.yang,
brocade-threshold-monitor.yang, and brocade-threshold-monitor-ext.yang files.

FRU monitoring

System Monitor monitors the absolute state of the fans, power supplies, CID card, line cards, and
SFPs. For a description of possible states, and hardware platform default threshold settings, refer
to the Network OS Administrator’s Guide.

Setting system thresholds

Each component can be in one of two states, down or marginal, based on factory-defined or
user-configured thresholds.

NOTE

You can disable monitoring of each component by setting the down threshold and the marginal
threshold to zero.

To set system threshold values, perform the following steps.

1. Issue the RPC to configure the node in the

urn:brocade.com:mgmt:brocade-system-monitor namespace.

2. Under the node, include a node element for each FRU for which you want to

configure the system thresholds.

Node elements that can have their system thresholds configured include , ,
, , , , , , and .

3. Under the node element designating the FRU, include the node element.

4. Under the node element, include the following leaf elements.

a. In the element, specify a minimum number contributing to the

MARGINAL status of the switch.

b. In the element, specify the minimum number contributing to the DOWN

status of he switch.

The following example sets the MARGINAL and DOWN threshold values for each FRU type.

1

2