Compliance, Standards, Power – Carrier Access Access Navigator User Manual
Page 78: Environmental, Physical
4-14
August 2003
Access Navigator - Release 1.8
Access Navigator / GR-303 Host with P-Phone
Compliance
Compliance
USA
l
UL 1950, 3rd Edition
l
FCC Part 15, Class A
l
FCC Part 68
l
NEBS Level 3 for Type 2 and 4 equipment
GR-1089-CORE
GR-63-CORE
CANADA
l
CSA C22.2 No. 950.95
l
ICES-003, Class A
l
CS-03
Standards
l
AT&T 62411 (Stratum 4 enhanced T1 CPE)
l
ANSI T1.403 and T1.107a
Power
l
Input power: –42 to –60 VDC @ 1.5A
l
Dual feed DC power input terminals
l
Power dissipation: 65 watts (225 Btu/hr.), fully equipped
l
Solid-state (fuse-less) over-voltage and over-current protection
Environmental
l
Operating temperature: –5°C to +45°C (23°F to 113°F), up to +55°C short term (NEBS)
l
Solid-state over-temperature protection
l
Relative humidity: 0 to 95%, non-condensing
l
No fans; Passive thermal management
Physical
l
Dimensions: 17" x 13.5" x 2.63"
l
Weight: 10 lbs. (4.54 kg)
l
Mounts in 19 and 23 inch racks
l
Optional wall mount brackets