Read remote performance, Read remote performance -52 – Carrier Access Access Navigator User Manual

Page 508

background image

18-52

August 2003

Access Navigator - Release 1.8

CLI Language Reference

CLI Command List

Message:

RS232:

Port type: Subrate

RTS: Not Asserted

DTR: Not Asserted

CTS: Not Asserted

CD: Not Asserted

Stop Bit: 1

Parity: none

Data Bits: 8

Baud Rate: 9600

Description:

Read Remote Performance

Purpose:

Reads and displays the performance statistics of a remote Access Bank II T1 or T1
Drop at the far end of the DS1. The interval timer in the Access Bank II is only reset
by a power-on reset or reset remote command. Consequently, the performance
measurements reflect data collected during the last 0 to 15 minutes of the current 15-
minute interval.

Security:

Level 3 (monitor)

Syntax:

read remote <n> <t1|t1drop> performance

Item

Description

Port type

Subrate – asynchronous data port.

RTS

Request to Send: Asserted, Not Asserted.

DTR

Data Terminal Ready: Asserted, Not Asserted.

CTS

Clear to Send: Asserted, Not Asserted.

CD

Carrier Detect: Asserted, Not Asserted.

Baud Rate

1200, 2400, 4800, 9600, 19200, 38400, 57600

Data Bits

7, 8

Parity

None, Odd, Even

Stop Bits

1, 2

Field

Description

n

DS1 number, 1 to 32.

t1

Read T1 performance statistics

t1drop

Read T1 Drop performance statistics