Carrier Access Access Navigator User Manual
Page 316
![background image](/manuals/63313/316/background.png)
13-20
August 2003
Access Navigator - Release 1.8
Provision Remote Adit 600 via IP DS0
Provision Drop DS0s to Remote Adit
NOTE:
In the above message, the channel type can be GR303 (voice or ISDN BRI), or
private crossconnects using VOICE or DATA. P-Phone settings only appear in the Access
Navigator / GR-303 Host with P-Phone. This procedure only provides steps for
provisioning GR-303 service. See also Provision DCS Service on
2. If drop DS0 settings are correct, skip remaining steps.
3. Set DS0 type. (ISDN BRI and P-Phone use gr303.)
set ds0
Example:
set ds0 10:1-18 type gr303
Example:
set ds0 10:19-24 type data
4. Set DS0 signaling (for voice only) to Loop Start (ls), Ground Start (gs), or E&M (em) signaling with
the following command:
set ds0
Example:
set ds0 10:1-18 signal ls
5. Set DS0 call reference value (needed for GR-303 ISDN BRI and P-Phone)
set ds0
Example:
set ds0 10:1 crv 120
6. Set DS0 in service
set ds0
Example:
set ds0 10:1-24 up