System Clocking

l

ANSI T1.403, Section 6 & 7 (jitter, pulse mask transmission, receive sensitivity, framing

formats)

l

Built-in CSU with loopback and BERT for testing the T1s

System Clocking

l

Primary and secondary sources from: DS1s, external clock source (such as BITS) or internal

clock (minimum Stratum 4)

l

Automatic clock switching and holdover

Signaling

l

Robbed-bit and clear channel connections at DS0 level

l

FXS/FXO loop start and ground start robbed bit signaling

l

E&M robbed bit signaling

Management Interfaces

l

Command line interface (CLI) for provisioning and maintenance

l

RS-232 interface for local CLI

l

Ethernet Telnet support for remote CLI

l

Ethernet SNMP uses Telcordia® standard MIB for DS1 interfaces (RFC-1406)

l

TFTP and Xmodem support for flash memory software upgrades

Protocols

l

Command Line Interface (CLI)

l

Simple Network Management Protocol (SNMP)

l

Telnet /TFTP

Alarms

l

Critical, Major, and Minor alarm levels

l

DS1 alarms for LOS, LOF, AIS, and RAI

l

Front panel LED indicators

l

Output signal: relay contact closure and LED indication

Maximum relay contact rating: 110V AC or DC @ 1A

l

Alarm inputs from dry contact closures

Maximum input rating: 60V DC