18-78

August 2003

Access Navigator - Release 1.8

CLI Language Reference

CLI Command List

After 10 seconds the pattern is turned off and the test results from the BERT are
displayed in a CLI message. (The send ds1 off command is not required to
turn off the pattern.)

Figure 18-11. Send DS1 Payload Pattern with BER Test

Security:

Level 2 (operator)

Syntax:

send ds1 payload

<allones|allzeros|f1in8|p2e11|p2e15|p2e23|qrss> test

Field

Description

n

DS1 number, 1 to 32, or a range of numbers such as 2-8.

allones

Send framed all-ones pattern. This can be used as a “keep alive”
signal, idle code, and in measuring the T1 power level.

allzeros

Send framed all-zeros pattern. This can be used to test T1 circuits
for B8ZS clear channel capability and to find equipment
incorrectly set to AMI line code.
Note: When using an all-zeros pattern, a T1 test set (such as a
T-Berd 224 or Sunset T3) must be used to monitor for errors in
the all-zeros pattern from the Access Navigator or looped back
from a far-end network element.

f1in8

Send framed 1-in-8 pattern (also called a 1-and-7 pattern) in
which each payload byte contains the bit pattern 01000000.
(Minimal ones density test for T1 circuits with AMI coding.)

DS1

Line

Interface

Unit

Framer

Access Navigator

Time Slot

Interchange

Code

Generator

Bit Error

Rate

Tester

Payload

Pattern

with BERT

Framed

Pattern

IN

OUT

CSU

Access Bank II

Far End

Payload Loopup

DS0s