Carrier Access Access Navigator User Manual
Page 393

Access Navigator - Release 1.8
August 2003
15-51
Diagnostics & Troubleshooting
Send DS1 Payload Pattern with BER Test
08:15:56 FBE:0 BE:0 CRC:0 BPV/LCV:0
08:15:57 FBE:0 BE:0 CRC:0 BPV/LCV:0
Totals Error Rates
FBE: 0 0.000000e+00
BE: 0 0.000000e+00
CRC: 0 0.000000e+00
LCV/BPV: 0 0.000000e+00
Signaling done.
The following error message will occur if an incorrect pattern is received:
Message:
Waiting for pattern sync.........no sync.
Example:
send ds1 9 payload f1in8 test
For the 1-in-8 and all-zeros patterns, the CLI will provide a progress message
indicating the success (ok) or failure of the command, followed by a pattern detection
message for each second of the test.
Message:
Waiting for pattern sync........ok.
Testing line...
08:18:23 Pattern Not Present
08:18:24 Pattern Present
08:18:25 Pattern Present
08:18:26 Pattern Present
08:18:27 Pattern Present
08:18:28 Pattern Present
08:18:29 Pattern Present
08:18:30 Pattern Present
08:18:31 Pattern Present
08:18:32 Pattern Present
Signaling done.