beautypg.com

Read remote loopback, Read remote rs232, Read remote loopback -51 – Carrier Access Access Navigator User Manual

Page 507: Read remote rs232 -51

background image

Access Navigator - Release 1.8

August 2003

18-51

CLI Language Reference

CLI Command List

Description:

Read Remote Loopback

Purpose:

Reads and displays the loopback status of the remote terminal on the specified DS1.

NOTE:

All read remote commands require that the remote Access Bank II

is operational and connected to an Access Navigator drop DS1 using Carrier
Access FDL management protocol.

Security:

Level 3 (monitor)

Syntax:

read remote loopback

Example:

read remote 9 loopback

Message:

Remote Port T1 in Equipment Payload loopup.

Read Remote RS232

Purpose:

Reads and displays the asynchronous RS-232 data port status and settings from the
remote Access Bank II at the far end of the Access Navigator’s DS1. The first five
items are status and the last four are settings. The Access Bank II must be operational
to read its settings. The command displays a message similar to the following.

Security:

Level 3 (monitor)

Syntax:

read remote <n> rs232

Example:

read remote 9 rs232

Item

Description

1) 2) 3) ...

Event number, starting with the most recent.

Time

Time of the event.

Date

Date of the event.

Description

Message describing the event.

Field

Description

n

DS1 number, 1 to 32

Field

Description

n

DS1 number, 1 to 32.