beautypg.com

Send ds1 line loopup, Send ds1 line loopup -63, Send ds1 line loopup on – Carrier Access Access Navigator User Manual

Page 519

background image

Access Navigator - Release 1.8

August 2003

18-63

CLI Language Reference

CLI Command List

Security:

Level 2 (operator)

Syntax:

send ds1 csu <loopup|loopdown>

Example:

send ds1 9 csu loopup

Message:

Loopup signal sent to remote.

Waiting for confirmation.....loopup confirmed.

The above message indicates that the loopup code was sent and that the Access
Navigator confirms that the far-end is in loopback. If the message ends with “unable to
confirm loopup” there may be a line or equipment problem in the DS1 loop. When
testing is finished, always use the loopdown command to return the far-end equipment
to normal operation.

Example:

send ds1 9 csu loopdown

Message:

Loopdown signal sent to remote.

Waiting for confirmation.....loopdown confirmed.

The above message indicates that the loopdown code was sent and that the Access
Navigator confirms that no loopback signal is being received from the far-end. If the
message ends with “loopup still present” the far-end equipment is still in loopback
mode.

If the code can not be sent, the CLI will display an error message, as in the following
example.

Message:

*- unable to set up ds1 because ds1 is reporting an alarm

condition.

Send DS1 Line Loopup

NOTE:

The DS1 must be set Out of Service, using the set ds1 down

command, before you can use loopbacks or test patterns.

NOTE:

For normal operation, the loopback must be disabled (loopdown).

NOTE:

This command works with ESF framing and T1.403 FDL, or with

SLC-96/TR-08 framing for Shelf A. For Shelves B, C, D, use the command
Send DS1 CSU Loopup on

page 18-62

. An Access Bank II using Carrier

Access FDL protocol will ignore this command.

Field

Description

n

DS1 number, 1 to 32, or a range of numbers such as 2-8.

loopup

Enable line loopback.

loopdown

Disable line loopback.