beautypg.com

Set system switch type, Set system clock source – Carrier Access Access Navigator User Manual

Page 228

background image

10-14

August 2003

Access Navigator - Release 1.8

Provision GR-303 Service

Set System Switch Type

Set System Switch Type

NOTE:

Access Navigator supports Lucent 5ESS, Nortel DMS, and generic Telcordia

GR-303 switch types.

1. Show switch type with the following command:

show switch

2. If switch type is correct, skip remaining steps.

3. Set switch type with the following command:

set switch type <5ess|dms|generic>

Example:

set switch type 5ess

Set System Clock Source

NOTE:

For GR-303 call support, the primary and secondary clock sources are usually

set to two DS1s within the GR-303 Interface Group.

1. Show current clock settings with the following command:

show clock

This command will produce a message similar to the following:

Primary Master Transmit Clock Source:

DS1 25

Secondary Master Transmit Clock Source:

DS1 29

2. If clock settings are correct, skip remaining steps.

3. Set clock primary (clock1) source with the following command:

set clock1

Example:

set clock1 bits

There are three different settings, which are defined as follows:

Setting

Definition

bits

Select external or BITS source on Timing In connector

ds1

Select clock recovered from DS1 number n

internal

Select internal oscillator

4. Set clock secondary (clock2) source with one of the following commands:

set clock2

Example:

set clock2 ds1 5

Choose setting from list in previous step.