Example:

send ds1 9 payload f1in8 test

For the 1-in-8 and all-zeros patterns, the CLI will provide a progress message
indicating the success (ok) or failure of the command, followed by a pattern detection
message for each second of the test.

Message:

Waiting for pattern sync........ok.

Testing line...

08:18:23 Pattern Not Present

08:18:24 Pattern Present

08:18:25 Pattern Present

08:18:26 Pattern Present

08:18:27 Pattern Present

08:18:28 Pattern Present

08:18:29 Pattern Present

08:18:30 Pattern Present

08:18:31 Pattern Present

08:18:32 Pattern Present

Signaling done.

Description:

Item

Description

Time

Time is recorded in one-second intervals. Format is 24-hour
clock in hours:minutes:seconds with colons to separate the digits,
as in 08:30:45 and 15:22:10.

FBE

Number of Frame Bit Errors (4095 maximum) in one-second
interval

BE

Number of Bit Errors (4095 maximum) in one-second interval

CRC

Number of Cyclical Redundancy Check errors (1023 maximum)
in one-second interval

BPV/LCV

Number of Bi-Polar Violations and Line Code Violations
(16,383 maximum) in one-second interval

Totals

Total number of errors for 10-second test interval

Error Rates

Total error rates measured during the 10-second test interval,
expressed in scientific notation where "e" indicates a power of
10. For example, 1 error per 1.544 megabits is 6.520000e-07.
The maximum value is 2.700000e-03.