beautypg.com

Precautions caution, Warning, Tools and materials required – Carrier Access Access Navigator User Manual

Page 427

background image

Access Navigator - Release 1.8

August 2003

16-29

Maintenance

Procedures

Install SIMM on Controller Card

Precautions

CAUTION!

S

ERVICE

DISRUPTIONS

WILL

OCCUR

IF

THE

ACTIVE

C

ONTROLLER

CARD

IS

REMOVED

WITHOUT

AN

OPERATIONAL

STANDBY

C

ONTROLLER

. T

O

AVOID

SERVICE

DISRUPTIONS

,

ALWAYS

REMOVE

THE

STANDBY

C

ONTROLLER

FIRST

. I

N

A

PROTECTED

SYSTEM

WITH

TWO

C

ONTROLLER

CARDS

,

THE

ACTIVE

C

ONTROLLER

SHOULD

BE

SWITCHED

TO

STANDBY

MODE

BEFORE

REMOVING

. I

N

AN

UNPROTECTED

SYSTEM

WITH

ONLY

ONE

C

ONTROLLER

CARD

, SIMM

INSTALLATION

WILL

DISRUPT

SERVICE

BUT

WILL

NOT

AFFECT

STORED

PROVISIONING

DATA

.

WARNING!

T

HE

A

CCESS

N

AVIGATOR

CONTAINS

CIRCUIT

CARDS

AND

COMPO

-

NENTS

THAT

ARE

SUBJECT

TO

DAMAGE

BY

ELECTROSTATIC

DISCHARGE

(ESD).

A

LWAYS

FOLLOW

THE

S

TATIC

-S

ENSITIVE

E

QUIPMENT

H

ANDLING

P

ROCEDURES

ON

page 6-3

WHEN

OPENING

EQUIPMENT

COVERS

AND

HANDLING

PLUG

-

IN

CIRCUIT

CARDS

.

Tools and Materials Required

Obtain the following tools and materials.

l

Office records for installation site

l

Screwdrivers, slotted

l

Grounding wrist strap

l

SIMM, 8 MB (included with software update 1.25)