Carrier Access Access Navigator User Manual
Page 394

15-52
August 2003
Access Navigator - Release 1.8
Diagnostics & Troubleshooting
Send DS1 Payload Pattern with BER Test
Description:
Item
Description
Time
Time is recorded in one-second intervals. Format is 24-hour
clock in hours:minutes:seconds with colons to separate the digits,
as in 08:30:45 and 15:22:10.
FBE
Number of Frame Bit Errors (4095 maximum) in one-second
interval
BE
Number of Bit Errors (4095 maximum) in one-second interval
CRC
Number of Cyclical Redundancy Check errors (1023 maximum)
in one-second interval
BPV/LCV
Number of Bi-Polar Violations and Line Code Violations
(16,383 maximum) in one-second interval
Totals
Total number of errors for 10-second test interval
Error Rates
Total error rates measured during the 10-second test interval,
expressed in scientific notation where "e" indicates a power of
10. For example, 1 error per 1.544 megabits is 6.520000e-07.
The maximum value is 2.700000e-03.