beautypg.com

Provision “groom” ds1 circuits to network, Provision “groom” ds1 circuits to network -12 – Carrier Access Access Navigator User Manual

Page 206

background image

9-12

August 2003

Access Navigator - Release 1.8

Provision DCS Service

Provision “Groom” DS1 Circuits to Network

Provision “Groom” DS1 Circuits to Network

1. Show groom DS1 settings with the following command:

show ds1

Example:

show ds1 10

The show command will produce a message showing the DS1 settings. For example, the message
for DS1 number 10 might look similar to the following:

Settings for DS1 10:
Circuit ID: CA DS1# 10
Up/Down: DOWN
Framing: ESF
Line Coding: B8ZS
Type: DROP
Clock Source: NORMAL
Line Build Out: DSX-1 EQUALIZATION FOR 0-133 ft.
Loop Code Detection: OFF
Loop Back: OFF
Line Termination ID: 0 (for switch DS1s only)
FDL Type: CAC
Send Code: None
Performance Thresholds: 15 min. 1 hour 1 day
-------- ------- ------
unavailable seconds: 0 0 0
severely errored seconds: 0 0 0
errored seconds: 0 0 0
sev. errored frame seconds: 0 0 0
degraded minutes: 0 0 0
linecode violations: 0 0 0

NOTE:

In the above message loop back test function is turned off and the send code

set to none during normal service. Line Termination IDs are used only for GR-303 switch
DS1s.

2. If groom DS1 settings are correct, skip remaining steps.

3. Set DS1 type to “groom” with the following command:

set ds1 type groom

Example:

set ds1 10 type groom

4. Set groom DS1 frame type to D4 or ESF with the following command:

set ds1 framing

Example:

set ds1 10 framing esf