Show Autoexit

Purpose:

Displays the current setting for the autoexit timeout.

Security:

Level 3 (monitor)

Syntax:

show autoexit

Message:

CLI session timeout = 15 minutes.

Show Clock

Purpose:

Displays the current settings for the primary and secondary master transmit clock
source.

Security:

Level 3 (monitor)

Syntax:

show clock

Message:

Primary Master Transmit Clock Source: DS1 12
Secondary Master Transmit Clock Source: INTERNAL

Description:

Show Connect

Purpose:

Displays static DS0 connections in the specified DS1. This display will list the current
static DS0 crossconnect settings and dynamic GR-303 voice and ISDN BRI
connections. If a DS0 is part of a fractional interface, the interface name will be shown.

For GR-303 service, the switch assigns GR-303 voice connections as needed, between
switch DS1s and drop DS1s. ISDN BRI using 4:1 TDM mode transport has the D
signaling channel statically connected to a switch DS0, while the switch only sets up
B1 and B2 bearer DS0s as needed between switch DS1s and drop DS1s.

NOTE:

ISDN BRI connections using the GR-303 4:1 TDM transport mode

will appear as type GR-303.

Item

Description

Clock Source

Clock source can be a DS1 line receiver, internal Stratum clock
oscillator, or external Building Integrated Timing Supply
(BITS).