10-10

August 2003

Access Navigator - Release 1.8

Provision GR-303 Service

Obtain Provisioning Information

Obtain Provisioning Information

1. Obtain office records for installation site.

2. Obtain circuit orders for GR-303 service turn up.

Verify System Equipment Configuration

CAUTION!

V

ERIFY

CURRENT

CONFIGURATION

AND

SERVICE

STATUS

WITH

OFFICE

RECORDS

BEFORE

ADDING

,

DELETING

,

OR

CHANGING

CIRCUITS

.

NOTE:

The factory default sets all DS1s and DS0s in-service (up). To prevent

inadvertent service disruptions, it is good practice to set circuits out of service (down) when
not in use or not provisioned in the switch. Set the type of unused DS0 channels to match
the DS0 type configured on the device at the other end of the DS1. If the DS1 is not
terminated, set the type to data.

1. Start management session (see Start Management Session on

page 7-1

).

2. Show system equipment configuration with the following command:

status equipment

A message similar to the following will appear, showing the equipment card slots, service status,
and Controller software version.

Equipment

Status

Version

---------

------

-------

Controller A

Active

01.70 GR-303 Option

Controller B

Standby

01.70 GR-303 Option

DS1 Card 1

Installed

1

DS1 Card 2

Installed

1

DS1 Card 3

Installed

1

DS1 Card 4

Installed

1

DS1 Card 5

Installed

1

set ds0 isdn <b1|b2|d> crv

ISDN BRI 4:1 TDM channels.

set ds0 crv

set ds0 crv slc96

Assign Drop DS0s to CRVs in sequential
order or in odd-even (slc96) order.

connect

Connect ISDN D channel to Switch.

set ds0 up

Set DS0s in service.

set ds1 up

Set DS1s in service.

CLI Commands

Descriptions