Access Navigator - Release 1.8

August 2003

18-89

CLI Language Reference

CLI Command List

Message:

Loop command sent to remote.

Send Remote T1Drop Payload Loopup

NOTE:

This command applies only to a remote Access Bank II connected

to the Access Navigator by a DS1 using Carrier Access FDL management
protocol. For normal operation, the loopback must be disabled by the send
remote

loopdown command.

NOTE:

Only one port of the Access Bank II can be looped up at a time. If a

loopup command is received for a second port, the first port will be looped down
automatically before the second port is looped up.

NOTE:

To check remote loopback status, use the read remote loopback

command. See Read Remote Loopback on

page 18-51

.

Purpose:

Sends an out-of-band (FDL) message to a remote Access Bank II over the Access
Navigator DS1. It is used to verify T1 Drop signal processing.

When the operator enters a send remote command, the Access Navigator transmits a
message over the Carrier Access FDL management channel of the drop DS1. The
Access Navigator’s drop DS1 is the Access Bank’s T1 connection.

The send remote t1drop payload loopup command should cause the remote
Access Bank II to perform a payload loopback on the T1 Drop interface. This takes the
received T1 Drop DS0s, loops them in the framer, and sends them back to the T1 Drop
output (see Figure 18-19). To loopdown the interface, use the send remote loopdown
command.

Figure 18-19. Remote T1 Drop Payload Loopup

Security:

Level 2 (operator)

DS0s

DS1

Access

Navigator

Framer

CA FDL

Command

Access Bank II

T1 Drop

Payload Loopup

T1

Framer

T1 Drop

Time Slot

Interchange